    Duplex, Enclosed Compressor System for Fueling Vehicles with Natural Gas (CNG): 10 to 100 HP, Air Cooled Design

MODEL:*(HP = total motor HP)

UR40DE - (HP)*

UR50DE - (HP)*

UR65DE - (HP)*

Manufacturer:

Universal Air Products GPD

Power (Electric Motor):*

10 to 40 HP*

20  to 30 HP*

60  to 100 HP*

Inlet Pressure:

1 inch WC or higher

1 inch WC or higher

1 inch WC or higher

Discharge Pressure:

6000 psig maximum

Flow (subject to inlet /outlet):

10  to 50 SCFM

20 to 70 SCFM

40 to 160 SCFM

Vehicles fueled / day:

Consult sales representative

Compression Stages:

4

4

4

Cooling System Design:

Air

Air

Air

Electrical Classification (USA)

NEC NEMA Design 7, Class 1, Division 2, Group C, D

Electrical Voltage / Hz

200 to 575V (50 or 60 Hz)

Electrical Phase (Ph)

1 Ph to 10HP; 3 Ph all HP

1 Ph to 10HP; 3 Ph all HP

3 Ph

                                                                                                       

                                                                                

                                                                                           * Larger HP Systems Available

 

       Additional NG Compression System Features Include:

 

     o   Structural steel base frame, fork-liftable

     o      Full system steel enclosure with oil-resistant, sound and ambient insulation; ventilation

                  louvers and fans; pitched roof with ridge vents, heat reflective roof panels; lift-off (trigger latch)

                  16 gauge steel access panels,

     o      PLC (programmable logic control)

     o      Digital message board with fault history and real time readings for all sensors

     o      Common fault indicator light for programmed shutdown conditions

     o      Duplex, full voltage motor starter and electrical control  system mounted and wired

     o      Control voltage circuit with  step-down transformer

     o      Motor overloads

     o     Power-on light

     o     Emergency kill (mushroom) switch

     o     On-off switch for start/stop control (two-way switch)

     o     Face gauge panel, including 1st stage thru final discharge pressure and oil pressure

     o     Face gauge for final system pressure prior to the pressure maintaining valve

     o     Discharge pressure sensor with infinite setting control and multiple set points

     o     Low and high inlet pressure sensor

     o     Low oil pressure sensor

     o     High outlet temperature sensor (1st & 4th stages)

     o     Contacts provided for remote monitoring of system controls

     o     Built-in air cooled intercoolers and aftercooler

     o     Moisture separation, all stages

     o     Auto condensate drainage, all stages

     o     Cartridge dryer / filtration manifold, installed

     o     Forced lubrication system with oil pump and filter

     o     Crankcase breather piped to inlet or vent (subject to inlet conditions)

     o     Automatic compressor unloading system with vented to vapor recovery tank

     o     Non-return valve at discharge

     o     Minimum pressure valve at discharge

     o     Finish paint in blue or light gray enamel

     o     ASME, inlet gas surge tank with pressure gauge and gas tight relief valve

     o     Integrated vapor recovery system with ASME storage vessel regulated to system inlet

     o     Detailed general arrangement, electrical and flow diagrams for customer review and approval

                 prior to system construction

     o    Detailed operations, maintenance and parts manuals provided in electronic or hard copy format 

                 (Standard English, alternate languages available at option)

 

Typical Feature/Options Available:

 

     o    Completely custom designs

     o    Larger horse power  ( kW)

     o    Water cooled compressor or aftercooler designs

     o    NEMA 7, Class 1, Division 1; rather than Division 2

     o    Loose starter and/or electrical controls for mounting remotely at the job site

     o    Reduced voltage starters (wye-delta, solid state or VFD)

            o    Wired / wireless (LAN and/or WAN) based controls with monitoring capabilities (HMI and/or SCADA)

     o    Combination style disconnect switch for the duplex motor starter

     o    Open frame design (elimination of the full system enclosure)

     o    Lockable, trigger latch door panels

     o    Roof drainage systems complete with gutters and drain pipe connections to skid’s edge

     o    Off-shore base frame (skid) design with lifting eye and drag provisions

     o    Low ambient protection

     o    Inlet pressure regulation

     o    Outlet pressure regulation

     o    Vapor recovery tank pressure or temperature sensors

     o    Analog controls rather than PLC

     o    Custom programming of the PLC:

Ø  Remote monitoring or controlling of the system

Ø  Customer site specific control or maintenance features

Ø  Remote operation, monitoring and diagnostics

     o    Engine driven designs

     o    High pressure storage tanks (ASME or DOT)

     o    Priority fill to high pressure gas storage

     o    Cascade fill to the vehicle gas storage

     o    Gas dispensing systems

     o    Custom inlet or discharge gas dryer in lieu of standard cartridge dryer manifold

     o    Inlet or discharge gas filtration

     o    Finish paint in epoxy and/or customer’s color selection

     o    Hot dip galvanized structural steel base frame

     o    System modifications for non-municipal fuel gases, including biogas, landfill, digester,

                 wastewater, Hydrogen and synthetic-gases.  (Typical gas analysis required)

     o    Installation & startup

     o    Aftermarket technical support or site services

     o    Manuals provided in languages other than English.

 

 

   